Sensors protection and flame arresting
ALUPOR team offers original solution for the sensors protection. The material will stop the dust and moisture and at the same time it will breathe. We are able to adjust material properties to ensure optimal sensitivity and permeability.
· low influence on sensor lag
· wide temperature range
· flexible adjustment of material parameters to exploitation conditions
· any size and shape
· attractive price
Material performance
Property |
Material type (graded by main pore size range), μm |
|||
100-200 |
140-315 |
200-400 |
315-630 |
|
Porosity, % |
55±5 |
|||
Exploitation temperature, °С |
-60…350 |
|||
Contaminant types |
Пыль, твердые частицы, капельная влага |
|||
Min size of contaminant cathed, μm |
5 |
10 |
25 |
50 |
Min wall thickness, mm |
1 |
1 |
1 |
1.5 |
Production
FER G(F) Series
Threaded protective housings
Model
|
Thread (female) |
D, mm
|
d, mm |
L, mm
|
h, mm
|
FER G(F)3-8 | G3/8" | 19 | 14 | 30 | 12 |
FER G(F)1-2 | G1/2" | 25 | 20 | 32 | 12 |
FER G(F)3-4 | G3/4" | 32 | 27 | 36.5 | 12 |
FER G(F)1 | G1" | 40 | 35 | 50 | 18 |
Any construction you want...